DIN Control Mechanical Accessories

 


 

DIN Rail Mounting

DIN Rail Mounting of traditional panel mount controls is easily accomplished with Future Design Control's DIN Rail Mounting accessories.

 

DRA-32 and DRA-16:

Virtually any brand of 1/32 and 1/16 DIN Controls can be DIN Rail Mounted using the DRA-32 or DRA-16 Universal Mounting Adapter

  DRA-16 DRA-32

                                      

Universal 1/32 or 1/16 DIN Controls.pdf 

------------------------------------------------------------------

The 9100 and P91 1/16 DIN Controls offer an optional DIN Rail Adapter that attaches to their rear terminal. This is space saving adapter provides a solution when using 1/16 DIN controls and DIN Rail space is at a premium.

 

   
9100 DIN Rail Mount Accessory

          

                                                        9100 Series Terminal Mounted DIN Rail.pdf

 

The 9100 is a member of the 100 Series Control Family offering 1/16 through 1/4 DIN controls and the P91 is a profile control.

100 Series Brochure.pdf

100 Series Manual.pdf

Link to 100 Series Page

P Series Profile Controls Page

 

Dimensional information: DIN Enclosure Size.htm


Terminal Covers

9090 Terminal Cover PID Control

Snap-on Terminal covers for 1/16, 1/8 and 1/4 DIN Controls

Terminal Covers.pdf

 

Applicable to the following Future Design Controls Models:

1/16 DIN Controls: 901, 902, 905, 9090, 9100, C91, L91, P91

1/8 DIN Controls: 805, 8120/30, 8100, 8300

1/4 DIN Controls: 401, 402, 404, 405, 4120, 4100, 4300, L41, P41

 


CT Sensor Input for 300 Series Controls

 

CT Sensor [0-50 amp] sensor for to Display amp & input for Heater Break Alarm

                       CT Sensor       CT Sensor Dimension

CT Sensor for 300 Series Input #2.pdf

 

The 300 Series Controls have a 2nd input that can be configured as a 2nd PV, Remote Setpoint or to accept the CT94-1 0-50 amp Current Transformer. 

 

With the CT94-1 and one output configured as a Heater Break Alarm the 300 Series will detect, display [0.1 amp resolution] heater current. An alarm setpoint value may be set when amp levels exceed desired range - out of range amp level will indicate a heater break condition.

 

Link to 300 Series Page

 

9300 full application manual.pdf [1.2MB]

[This manual documents 300 Series configuration of CT Sensor and alarm type.

 

Notes:

The CT94-1 can detect a full-wave AC current only; a DC or half-wave AC cannot be measured.

 

When used with time proportioning output a cycle time of at least 1 second is required for the A/D converter to measure the signal.

 


Part Number Listing for Output Modules Applicable to 100, 200, 300, C, L and P Series Controls

 

Part Number Listing for Output Modules

Applicable to 90, 100, 200, 300, C, L and P Series Controls

DIN Controls Output Module Part #.pdf 

 

 