FDC-2010-K5C - Web Server
click on either display for larger graphic
Page being updated to reflect ver 2.1
FDC-2010-K5C (Main View) Runtime Menus:
The FDC-2010-K5C runtime menu system provides a familiar, easy to use interface while reducing screen “clutter” by eliminating extra buttons required for navigation. Each series of interface screens will have their own series of menus specifically focused on the tasks for the specific screen.
Shown above are the “top” level menus when the FDC-2010-K5C runtime first loads. A Help menu exist for every screen but is not shown in the menu items above.
Setup Menu: The setup menu provides access to system and controller setup options. These options include decimal point selection, enable Web Page Server, Fan setup, Temperature Alarm Setpoints, Control Tuning, schedule recovery options when power is lost / recovered, Output Monitor, as well as offline settings for degree C/F, Setpoint Limits, Input Offsets, Force System Outputs and date/time.
This page describes Web Page Server - click here for more detail on other items described in the Setup Menu Kiln System User Settings.htm.
The remaining Menu items, View/Main View, Schedule, Setup, Log & Security are described in their own sections.
Setup Menu System - Web Server Selection

If the FDC-2010-K5C is plugged into an Ethernet connection (FDC-2010-K5C ships configured for “DHCP”), the IP address of the unit will be displayed. DHCP means “Dynamic Host Configuration Protocol”. This is a term used when a device (FDC-2010-K5C) is hooked to an Ethernet connection and the main system (router) automatically assigns the IP address when the device (FDC-2010-K5C) is powered up. The “Web Server Enabled” checkbox turns on or off the FDC-2010-K5C unit from serving web pages that are accessible via a local Intranet or World Wide Web (wired or wireless). The main setup screen also allows the user to select the decimal position for reading/writing dry bulb and wet bulb values.
Connect to the FDC-2010-K5C using Microsoft’s Internet Explorer

After the FDC-2010-K5C is connected to an Ethernet connection and the IP address is assigned by the system, write down the IP address shown on the above screen (use actual address show on FDC-2010-K5C display). Start Internet Explorer from any PC on the local network.
In the “Address” toolbar of Internet Explorer type: http://198.122.6.101/Orion.html (use actual IP address shown on your FDC-2010-K5C screen). The following page will be displayed and updated every 30 seconds automatically with new data from the FDC-2010-K5C system. All kiln data is provided for “view only” access.
Return to: Main Kiln FDC-2010-K5C Page
Pallet Heat-Treat operational mode Pallet_Heat-Treat.htm
Kiln Information Links below:
Kiln mode: Primary Operator Display Views.htm
Main Views, Monitor Probes, Set Manual Outputs, Trending, Alarm Monitor & History and Audit Trail
Pallet Heat-Treat operational mode - see Pallet_Heat-Treat.htm
Kiln mode: Main Schedule Views.htm
Drying Schedule View, Schedule Edit/Run, Schedule Run, Hold, Stop; Drying Schedule View, Schedule Entry, Plot Schedule, Edit Schedules, Run Schedule, Advance to Next or Previous Stage and Add Subtract Time.
Kiln mode: Additional Temperature Monitor Sensors.htm
Optional temperature Monitor sensors; monitor only or used as additional Core Temperatures for Kiln Heat-Treat/Sterilize.
Kiln mode: Kiln EMC Operation.htm:
Description of EMC calculated values shown on Kiln's Main View and control logic if so configured.
Kiln mode: PC based KilnView Software Package.htm:
KilnView PC Software Review - communicate with up to 16 FDC-2010-K5C Controls as well as up to 48 single loop controls (applies to FDC-2010-K5C Kiln operational mode only; KilnView may not be used in the Pallet Heat-Treat operational mode).
Pallet Heat-Treat Sterilization Mode.htm
Review of Pallet Heat-Treat Sterilization mode; available configurations, control logic, operation, etc.
Links below offer descriptions common to both the Kiln & Pallet Heat-Treat operational modes and/or configuration
Data Logging & View Historical Data.htm:
System Data Logging Start: Kiln mode on start up, on Schedule Start or on Demand and in Pallet Heat-Treat mode on cycle start. History Data View and printing as graph or averages with High & Low values, etc. File Utilities to manually copy and/or delete Historical Data, Alarm, Audit and Schedule files and if connected to LAN, FTP Historical Data files to PC based FTP Server.
Description of LAN standard features: Remote Access (embedded VNC Server), email/SMS text on alarm, FTP of Historical Data files (embedded FTP client), Web page (embedded web page server) & Atomic Clock time/date update
Print Data Views, Historical Data files including Data Log files, Alarm files, Audit Trail files, Recipe files, etc.
System Security & Audit Trail.htm:
Multi level Security & Audit Trail Setup.
Import/Export Data Log, Schedule, Alarm & Audit directories from Compact Flash Card to I-Stick Memory via USB port.
User Configurable FDC-2010-K5C Settings: Decimal Point, Control Tuning, LAN settings, Input Offsets, Temperature Alarm Setpoints, Remote I/O Monitor, Degrees C/F, Setpoint Limits, Force System outputs allowing easy testing of all outputs without running control system, Kiln mode Fan Direction & Dwell Times, Kiln mode Schedule Recovery [Power Loss] and more.
OEM FDC-2010-K5C Control System Configuration as Kiln only, Pallet Heat-Treat only or Combination Kiln & Pallet Heat-Treat control system. Configure control outputs as relay on/off or analog output; Configure Linear Outputs as either Control or Retransmission of Dry & Web Bulb setpoints or temperatures; Names for Digital Inputs, Control & Alarm Outputs, Event Outputs; Configure up to 7 DI that can disable Control outputs and logic [schedule hold, heat enable, Fans, Spray Auto, etc.]; Configure additional Monitor / Core Temperature inputs
Information to schedule an on-line demonstration of the FDC-2010-K5C control system
Information on multi-language Help screens, Audio output and on-board tools to troubleshoot control system.
Review of features that if connected to 3rd party energy monitoring devices (Load Monitor / Shedding) to reduce energy costs by wiring digital inputs to start/stop/hold schedules and/or disable specific outputs until appropriate.
Panel Mount USB Adapter, standard and Nema 4X, providing front panel access to USB port for memory I-Stick and/or printing direct from the FDC-2010-K5C interface.
Dimensional Drawings, mechanical specifications and sample wiring diagrams.
FDC-2010-K5C Contact Techncial Support and Touch Screen Software Updates.htm
Contact information & links to download touch screen software updates.